Place the machine on a relatively level surface or inside a vehicle cargo area. Carefully inspect the entire unit for any loose components, paying particular attention to the connection between the motor and the oil pump; ensure this connection is secure and properly aligned (concentric).
Connect the power supply correctly. Start the oil pump and check for the correct direction of rotation; if the rotation is incorrect, swap the power phase sequence.
Connect and securely fasten the oil inlet and outlet hoses. Users are advised to ensure the outlet hose and outlet port are tightly secured; otherwise, rising pressure could cause the outlet hose to blow off, resulting in unnecessary complications.
Once the inlet and outlet hoses are secured, press the motor start button. The oil pump will begin normal operation, and the oil discharged after passing through the three-stage filtration system will be purified oil.
When switching from one container (or tank) of oil to another, act quickly to prevent the oil pump from idling for an extended period. If the switch cannot be made in time, shut down the machine and restart it only after the inlet hose has been properly connected to the new container.